Print this page Email this page

Environmental ratings for enclosures based on Ingress Protection (IP) Code designations

First numeral
  • Degrees of protection against access to hazardous parts
  • Degrees of protection against solid foreign objects
Second numeral Degrees of protection against water

0

Non-protected

 

0

Non-protected

1

  • Protected against access to hazardous parts with the back of a hand
  • Protected against solid foreign objects of 50 mm and greater

1

Protected against vertically falling water drops

2

  • Protected against access to hazardous parts with a finger
  • Protected against solid foreign objects of 12,5 mm and greater

2

Protected against vertically falling water drops when enclosure tilted up to 15°

3

  • Protected against access to hazardous parts with a tool
  • Protected against solid foreign objects of 2,5 mm and greater

3

Protected against spraying water

4

  • Protected against access to hazardous parts with a wire
  • Protected against solid foreign objects of 1,0 mm and greater

4

Protected against splashing water

5

  • Protected against access to hazardous parts with a wire
  • Dust-protected

5

Protected against water jets

6

  • Protected against access to hazardous parts with a wire
  • Dust-tight

6

Protected against powerful water jets

 

7

Protected against the effects of temporary immersion in water

8

Protected against the effects of continuous immersion in water

Note: UL can provide testing and certification services to verify and document conformity of products for any of the above Enclosure "IP Codes."

Order the complete text of these certification documents through Global Engineering Documents