##  [Membrane Penetrations in Fire Resistance Rated Walls: Key Considerations and Standards](/thecodeauthority/knowledge/membrane-penetrations-fire-resistance-rated-walls) 

  Fact sheet

# Membrane Penetrations in Fire Resistance Rated Walls: Key Considerations and Standards

Explore membrane penetrations in fire resistance rated walls, focusing on key standards, and installation techniques.

  [ Contact us ](mailto:ULRegulatoryServices@ul.com)  

    ![UL Solutions Abstract Graphics - Donut](https://delivery-p133222-e1298791.adobeaemcloud.com/adobe/assets/urn:aaid:aem:0f7034b8-393e-4359-8a29-c7e2982bbfee/as/0f7034b8-393e-4359-8a29-c7e2982bbfee.webp?&smartcrop=Landscape&max-quality=90&width=400) 

 

 *play\_arrow* *pause* 

 ## Breadcrumb

 - [ *keyboard\_arrow\_left* Knowledge Center ](/thecodeauthority/knowledge)
- [ Home ](/)  *pen\_size\_1*
- [ The Code Authority® ](/thecodeauthority)  *pen\_size\_1*
- [ Knowledge Center ](/thecodeauthority/knowledge)  *pen\_size\_1*
- Membrane Penetrations In Fire Resistance Rated Walls: Key Considerations and Standards
 
  

 

 

  Membrane penetrations help protect electrical boxes in fire-resistance rated wall assemblies and are an essential part of fire safety to maintain model code required fire containment. To achieve the expected hourly fire-resistance rating, these assemblies must be constructed and maintained according to the criteria in the UL Solutions design and installation specifications. If the outer membrane of the wall assembly includes penetrations or recessed fixtures, these are required to be protected to maintain the hourly fire resistance-rating.





 

 

 ## Membrane penetrations versus through penetrations



There are two types of penetrations to be considered. A through penetration has an opening that passes entirely through a fire-resistance rated assembly, whereas a membrane penetration has an opening that only passes through one side of the assembly. For example, a recessed electrical box mounted in a gypsum board wall surface of a fire-resistance rated wall, with conductors in the wall cavity is a membrane penetration. The focus of this article is UL Certified products for membrane penetration.





 

 

  ## Access UL Product iQ®

For complimentary access to information on thousands of UL Certified products, components and materials.



  [ Access Product iQ® ](https://productiq.ulprospector.com/en)  

 

   ![man and woman in suits and hard hats on the floor of a testing facility](https://delivery-p133222-e1298791.adobeaemcloud.com/adobe/assets/urn:aaid:aem:bbfbe33d-2207-4fe7-a788-43ce825d3338/as/bbfbe33d-2207-4fe7-a788-43ce825d3338.webp?&smartcrop=Landscape&max-quality=90&width=400)  

 

 

 

 ## Code requirements for membrane penetrations



The International Building Code (IBC) requires membrane penetrations of fire-resistance rated assemblies by recessed fixtures to be protected so that the required fire resistance is maintained. It includes specific conditions by which electrical boxes may be installed in the wall. There are prescriptive Exceptions to the IBC requirements that recognize conditions under which recessed steel electrical boxes on opposite sides of a wall are protected with listed putty pads or are separated by other listed materials and methods.





 

 

 ## UL Classifications for membrane penetration



UL Solutions classifies putty pads and other listed materials and methods under the UL Solutions product category Wall Opening Protective Materials ([CLIV](https://iq.ulprospector.com/en/_?p=10005,10048,10006,10047&qm=q:CLIV) or [QCSN](https://iq.ulprospector.com/en/_?p=10005,10048,10006,10047&qm=q:QCSN)). This category covers three types of technologies: putty pads, insert pads and gaskets. Putty pads are putty-like products installed on the outer surfaces of an electrical box prior to installation in the gypsum board membrane on the wall. Insert pads are for installation on the inside back surface of the box. Finally, gaskets are for installation under the cover plate of the box. The latter two products may be installed after the gypsum membrane is in place. Each of these products are Classified for use in specific types of fire-resistive designs when installed in accordance with the details provided in each Classification.





 

 

The information in each Classification includes:

- The model numbers covered.
- The type and size of electrical box covered.
- A description of the fire-resistance rated wall assembly.
- The specific method for the installation of the product.
- The type of cover plate covered.
- The required spacing between boxes on opposite sides of the wall.
 
 

 

 

 ## Nonmetallic boxes in fire-rated assemblies



The Wall Opening Protective Materials section also permits the installation of nonmetallic electrical boxes in fire-resistance rated wall assemblies when the boxes are tested for use in fire-resistance rated walls and are installed in accordance with the instructions provided with the listing. Unlike metallic boxes, nonmetallic boxes intended for use in fire-resistance rated assemblies must be specifically listed for use in such assemblies.

UL Solutions classifies nonmetallic electrical boxes under the product category Outlet Boxes and Fittings Classified for Fire-Resistance ([CEYY](https://iq.ulprospector.com/en/_?p=10005,10048,10006,10047&qm=q:CEYY) or [QBWY](https://iq.ulprospector.com/en/_?p=10005,10048,10006,10047&qm=q:QBWY)). These nonmetallic boxes are Classified for use in specific types of fire-resistive designs when installed in accordance with the details provided in each Classification.





 

 

The information in each Classification includes:

- The model numbers covered.
- A description of the fire-resistance-rated wall assemblies covered.
- The annular space between the box and the wall membrane.
- The spacing limitations for the boxes.
- Other specific requirements or limitations of the Classification.
 
 

 

 

 The electrical boxes covered in this category are required to be marked with the UL in a circle located in the base of the box, Class X hr, where X indicates the maximum hourly rating (i.e., 1 hr or 2 hr), and F, W, and/or C, where F = Floor, W = Wall, and C = Ceiling.

Classifications for putty pads, insert pads, gaskets and nonmetallic electrical boxes can be found online using Product iQ®.





 

 

 

 

  

  ![UL Solutions](/modules/custom/ul_component/components/brand_element/assets/brand-element-positive/mobius.svg) ![UL Solutions](/modules/custom/ul_component/components/brand_element/assets/brand-element-reverse/mobius.svg)

## Looking for support?

Resources, support, and expertise to help you when you need it, wherever the job takes you. Join the community today.



 

  [ Join us *arrow\_forward* ](/thecodeauthority/community)  

  

 

 

  ## Related resources



 

 

 

 ### Carbon Monoxide Alarm Considerations for Code Authorities

Obtain a basic understanding of CO poisoning, CO alarms, how they are Listed, and how they are to be installed and maintained.

 

  [ Learn more *arrow\_forward* ](/thecodeauthority/knowledge/carbon-monoxide-alarm-codes)  

  

 

 ### Grounding and Bonding with Concentric and Eccentric Knockouts

Learn NEC® grounding and bonding requirements for concentric and eccentric knockouts in electrical enclosures. Help to ensure safe installations over 250V.

 

  [ Learn more *arrow\_forward* ](/thecodeauthority/knowledge/grounding-bonding-concentric-eccentric-knockout)  

  

 

 ### Line Side Connectors

Learn NEC® requirements for wire connectors used for splicing or tapping conductors on the line side of service equipment to be Certified (Listed) as suitable for this use.

 

  [ Learn more *arrow\_forward* ](/thecodeauthority/knowledge/nec-line-side-connectors)  

  

 

 ### Plywood Panels in UL Fire-Resistant Wall Assemblies

Learn the criteria under which plywood panels can be added to a UL fire-resistance rated wall assembly to increase structural stability.

 

  [ Learn more *arrow\_forward* ](/thecodeauthority/knowledge/plywood-fire-rated-ul-wall-assemblies)  

  

 

 ### UL 142 Aboveground Flammable Liquid Tanks

Understand the certification and key installation considerations and key installation considerations applicable to installation of the flammable liquid tanks and the related systems.

 

  [ Learn more *arrow\_forward* ](/thecodeauthority/knowledge/ul142-aboveground-flammable-liquid-tanks)  

  

 

 ### Understanding Fire Rated Ducts

Explore the different types of fire-rated ductwork and how to find the right fire-rated duct solution.

 

  [ Learn more *arrow\_forward* ](/thecodeauthority/knowledge/fire-rated-ducts-types-and-assemblies)  

  

 

 

 

 

 

   ## Download our resources



 

 

 

   PDF ### UL Solutions - Firestop and Joint Application Guide 

UL.com Document

 

  [ Download PDF *arrow\_forward* ](https://delivery-p133222-e1298791.adobeaemcloud.com/adobe/assets/urn:aaid:aem:b28c8332-f5b4-4ae5-9a19-97627600788f/original/as/Firestop-and-Joint-application-guide-final-draft-4-29-24pm-1.pdf)   [ Download PDF *download* ](https://delivery-p133222-e1298791.adobeaemcloud.com/adobe/assets/urn:aaid:aem:b28c8332-f5b4-4ae5-9a19-97627600788f/original/as/Firestop-and-Joint-application-guide-final-draft-4-29-24pm-1.pdf) 

  

 

 

   ## Explore The Code Authority®



 

 

 

   ![Rear view of a businesswoman wants to ask the question on a seminar in a board room.](https://delivery-p133222-e1298791.adobeaemcloud.com/adobe/assets/urn:aaid:aem:6b32743f-588e-4e20-883f-55ec8e0b5765/as/6b32743f-588e-4e20-883f-55ec8e0b5765.webp?&max-quality=90&width=400) 



### Events

Discover where our codes and regulatory services experts will be presenting or attending meetings.



 

  [ View events *arrow\_forward* ](/thecodeauthority/events)  

 

 

   ![Apprentice builders learning about specialist equipment in training facility](https://delivery-p133222-e1298791.adobeaemcloud.com/adobe/assets/urn:aaid:aem:fff06a9e-1492-4478-96bc-30c7539bcdbe/as/fff06a9e-1492-4478-96bc-30c7539bcdbe.webp?&max-quality=90&width=400) 



### Experts

Our team of experts brings extensive, cross-industry expertise and is ready to help you overcome the challenges you face in the field.



 

  [ Meet our experts *arrow\_forward* ](/thecodeauthority/meet-our-experts)  

 

 

   ![Pacific Islander construction worker using digital tablet](https://delivery-p133222-e1298791.adobeaemcloud.com/adobe/assets/urn:aaid:aem:00f9d406-c10c-4b3d-8329-fba71e1baecf/as/00f9d406-c10c-4b3d-8329-fba71e1baecf.webp?&max-quality=90&width=400) 



### Knowledge Center

Explore a comprehensive hub of resources designed to help keep you informed and code-compliant.



 

  [ View resources *arrow\_forward* ](/thecodeauthority/knowledge)  

 

 

   ![Team of Diverse Professional Heavy Industry Engineers Wearing Safety Uniform and Hard Hats Working on Laptop Computer. African American Technician and Female Worker Talking on a Meeting in a Factory.](https://delivery-p133222-e1298791.adobeaemcloud.com/adobe/assets/urn:aaid:aem:7818f55d-333b-47c8-9e1d-fd5dbd69931c/as/7818f55d-333b-47c8-9e1d-fd5dbd69931c.webp?&max-quality=90&width=400) 



### The Code Authority®

Access expertise, support and resources for Code Authorities.



 

  [ Learn more *arrow\_forward* ](/thecodeauthority)  

 

 

   ![Manager instructing a diverse team of engineers, blue collar workers and quality inspectors at a factory - Manufacturing concepts](https://delivery-p133222-e1298791.adobeaemcloud.com/adobe/assets/urn:aaid:aem:453e977e-9c93-45e0-ac3c-5a70d8686124/as/453e977e-9c93-45e0-ac3c-5a70d8686124.webp?&max-quality=90&width=400) 



### The Code Authority® Community

Join the Code Authority community for insights, news, regulatory updates and topics that matter to you.



 

  [ Learn more *arrow\_forward* ](/thecodeauthority/community)