Chinese hazardous locations certification documentsProtection method specific documentsGB3836.1-2000 Electrical apparatus for explosive atmospheres - General requirements (corresponding to IEC 60079-0 1998 Third edition) GB3836.2-2000 Electrical apparatus for explosive atmospheres - Flameproof electrical apparatus "d" (corresponding to IEC 60079-1 1990 Third edition) GB3836.3-2000 Electrical apparatus for explosive atmospheres - Increased safety electrical apparatus "e" (corresponding to IEC 60079-7 1990 Second edition) GB3836.4-83 Electrical apparatus for explosive atmospheres - Intrinsically safe circuits and electrical apparatus "i" (corresponding to IEC 60079-3 1990 Third edition and IEC60079- 11 1991 Third edition) GB3836.5-87 Electrical apparatus for explosive atmospheres - Pressurized electrical apparatus "p" (corresponding to IEC 60079-2 1983 Second edition) GB3836.6-87 Electrical apparatus for explosive atmospheres - Oil immersed electrical apparatus "o" GB3836.7-87 Electrical apparatus for explosive atmospheres - Powder filling electrical apparatus "q" GB3836.8-87 Electrical apparatus for explosive atmospheres - Non-sparking electrical apparatus "n" (corresponding to IEC 60079-15 1987 First edition) GB3836.9-90 Electrical apparatus for explosive atmospheres - Encapsulated electrical apparatus "m" (corresponding to IEC 60079-18 1992 First edition) GB3836.10-91 Electrical apparatus for explosive atmospheres - Hermetically sealed electrical apparatus "h" GB3836.11-91 Electrical apparatus for explosive atmospheres - Method of test for ascertainment of maximum experimental safe gap (corresponding to IEC 60079-1A 1975) GB3836.12-91 Classification of mixtures of gases or vapours with air according to their maximum experimental safe gaps and minimum igniting currents (corresponding to IEC 60079-12 1978 First edition) GB3836.13-1997 Electrical apparatus for explosive atmospheres - Repair and overhaul for electrical apparatus used in explosive gas atmospheres (corresponding to IEC 60079-19 1993 First edition) GB12476.1-90 Electrical apparatus for explosive atmospheres - Dust ignition-proof apparatus GB15322-94 Technical requirements and test methods for combustible gas detectors Ex Motor specific documentsJB7565-1999 Specifications for series YB flameproof three phase induction motors (Frame size 63~355) JB8973-1999 Requirements of explosion protected technique for increased safe brushless excitation synchronous motor JB8974-1999 Specifications for series TAW Increased safe brushless excitation synchronous motors JB8972-1999 Specifications for series YA Increased safe three phase induction motors (Frame size 315~355) JB9593-1999 Specifications for series YBK flameproof three phase induction motors for underground coal mines (Frame size 100~315) JB9595-1999 Specifications for series YA Increased safe three phase induction Motors (Frame size 80~280) JB9596-1999 Specifications for series YB-W,YB-TH,YB-WTH flameproof three phase induction motors (Frame size 80~315) JB8620-1997 Specifications for series YBDF2 flameproof three phase induction motors used with valve electrical devices JB8671-1997 Specifications for series YBGB,YBGB-W flameproof three phase induction motors used with duct pump (Frame size 80~315) JB8672-1997 Specifications for series YBJ flameproof three phase induction motors used with winder JB8673-1997 Specifications for series YB flameproof three phase induction motors used with muck loader JB8674-1997 Specifications for series YB high voltage flameproof three phase induction motors (Frame size 355~450) JB6762-1993 Flameproof immersible pump for underground coal mines JB6763-1993 Specifications for series YA-W, YA-WF anti-corrosion and increased safe three phase induction Motors used for outdoor and indoor (Frame size 80~280) JB6200-1992 Specifications for series YAO small power Increased safe three phase induction Motors (Frame size 56~90) JB6201-1992 Specifications for series YBDC flameproof capacitor start motor single phase induction Motors (Frame size 71~100) JB6202-1992 Specifications for series YBF flameproof three phase induction motors used with fan (Frame size 63~160) JB6217-1992 Specifications for series PB flameproof canned motors JB5337-1991 Specifications for series YW no-spark three phase induction motors (Frame size 80~315) JB5338-1991 Specifications for series YB flameproof (dIICT4) three phase induction Motors (Frame size 80~315) JB5869-1991 Specifications for series YBZS flameproof double-speed three phase induction motors for crane JB/T6455-1992 Specifications for series YB-H flameproof three phase induction ship motors (Frame size 80~280) JB/T56018-1999 Product quality grade for flameproof canned motor Back to the Certification Documents page Order the complete text of these certification documents through Global Engineering Documents For comments or questions on this page, please contact hazloc@ul.com. |
Home About UL HazLoc What Are Hazardous Locations? Global Vision Certification Services Training and Education European System North American System Technical Summary Certification Documentss Equipment Directory Trade Shows & Industry Conferences Contact Us Print this Page E-mail this Page |
|