MyHome will be down for maintenance between 6:00 PM CST on Saturday October 6th and 1:00 PM CST on Sunday October 7th.

UL Worldwide
North America
Europe
Denmark
France
Germany
Sweden
Switzerland
U.K.
Latin America
Asia Pacific
Argentina
Brazil
Mexico
Australia
India
Malaysia
New Zealand
Thailand
Hong Kong
Singapore
A study dedicated to exploring and better understanding the way people think and feel about the products they make or consume, the role this plays in shaping global trade and the impact this has on how products are conceived, constructed, sold and delivered.
more
UL is proud to share New Science, a powerful initiative showcasing important ways we are making our world safer through fundamental discovery, testing methodologies, software and standards across three initial areas.
more
Helping safe, compliant products to reach the global marketplace.
more
Delivering a breadth of services for the growing area of sustainability.
more
Leveraging UL's engineering, safety and performance expertise for the critical systems essential to our well-being.
more
Delivering product testing and assessments demanded by the global supply chain.
more
Offering training, advisory services and thought leadership to give businesses a competitive edge.
more
Share

Catalog of Standards

Browse the Catalog of Standards

UL 10B

Standard for Fire Tests of Door Assemblies

1.1 These methods of fire tests are applicable to door assemblies of various materials and types of construction for use in wall openings to retard the passage of fire.

1.2 Tests made in conformity with these test methods register performance during the test exposure; and such tests shall not be construed as determining compliance for use after exposure to fire.

1.3 It is the intent that tests made in conformity with these test methods develop data to enable regulatory bodies to determine the compliance of door assemblies for use in locations where fire resistance of a specified duration is required.

1.4 These methods are intended to evaluate the ability of a door assembly to remain in an opening during a predetermined test exposure.

1.5 The tests expose a specimen to a standard fire exposure controlled to achieve specified temperatures throughout a specified time period, followed by the application of a specified standard fire hose stream. The exposure, however, is not representative of all fire conditions, which vary with changes in the amount, nature, and distribution of fire loading, ventilation, compartment size and configuration, and heat sink characteristics of the compartment. It does, however, provide a relative measure of fire performance of door assemblies under these specified fire exposure conditions.

1.6 Any variation from the construction or conditions that are tested is capable of substantially changing the performance characteristics of the assembly.

1.7 The methods do not provide the following:

a)    Full information as to performance of all door assemblies in walls constructed of materials other than those tested.

b)    Evaluation of the degree by which the door assembly contributes to the risk of fire by generation of smoke, toxic gases, or other products of combustion.

c)    A temperature limit on the unexposed side of the door assembly.

d)    A limit on the number of openings intended in glazed areas or of the number and size of lateral openings between the door and frame.

e)    Measurement of the degree of control or limitation of the passage of smoke or products of combustion through the door assembly.