MyHome will be down for maintenance between 6:00 PM CST on Saturday October 6th and 1:00 PM CST on Sunday October 7th.

UL Monde
Amérique du Nord
Europe
États-Unis
Danemark
France
Allemagne
Suède
Suisse
Royaume-Uni
Amérique latine
Asie pacifique
Argentine
Brésil
Mexique
Australie
Inde
Malaisie
Nouvelle-Zélande
Thaïlande
Hong Kong
Singapour
A study dedicated to exploring and better understanding the way people think and feel about the products they make or consume, the role this plays in shaping global trade and the impact this has on how products are conceived, constructed, sold and delivered.
more
UL is proud to share New Science, a powerful initiative showcasing important ways we are making our world safer through fundamental discovery, testing methodologies, software and standards across three initial areas.
more
Contribuer au lancement de produits sûrs et conformes aux normes sur le marché international.
suite
Fournir un éventail de services dans le domaine sans cesse croissant du développement durable.
suite
Mettre à profit l'ingénierie et l'expertise d'UL en matière de sécurité et de performance pour les systèmes critiques essentiels à notre bien-être.
suite
Fournir les tests et les évaluations de produits exigés par la chaîne d'approvisionnement mondiale.
suite
Offrir des formations, des services de conseil et un leadership éclairé donnant un avantage concurrentiel aux entreprises.
suite
Industries
Services

Global Market Access

Faites d’UL votre partenaire pour vous guider dans l’environnement réglementaire des marchés mondiaux. Nous offrons des solutions intégrées d’essais de sécurité et de compatibilité électromagnétique, d’approbations d'appareils sans fil et de services d’efficacité énergétique.

suite
Share

Catalog of Standards

Browse the Catalog of Standards

UL 10D

FIRE TESTS FOR FIRE PROTECTIVE CURTAINS

1.1 These requirements cover the evaluation of fire protective curtains intended to provide supplemental, passive fire protection as part of an engineered fire protection system. Fire protective curtains provide nonstructural separation only, and are not intended to be employed where structural hourly rated partitions or protectives that have been tested for fire endurance and hose stream performance are required by code.

1.2 Tests made in conformity with these test methods are intended to register performance during the test exposure; but such tests shall not be construed as determining suitability for use after exposure to fire.

1.3 It is the intent that tests made in conformity with these test methods allow for the development of data to enable regulatory bodies to determine the suitability of fire protective curtains for use in locations where fire resistance of a specified duration is required.

1.4 These methods are intended to evaluate the ability of fire protective curtains to remain in an opening during a predetermined test exposure.

1.5 The tests expose a specimen to a standard fire exposure controlled to achieve specified temperatures throughout a specified time period. The exposure, however, is not representative of all fire conditions, which vary with changes in ventilation and compartment size and configuration. It does, however, provide a relative measure of fire performance of fire protective curtains under these specified fire exposure conditions.

1.6 Any variation from the construction or conditions that are tested is capable of substantially changing the performance characteristics of the fire curtain system.

1.7 The methods do not provide the following:

a)    Full information as to performance of all fire protective curtains in walls constructed of materials other than those tested.

b)    Evaluation of the degree by which the fire protective curtain contributes to the risk of fire by generation of smoke, toxic gases, or other products of combustion.

c)    A temperature limit on the unexposed side of the fire protective curtain.

d)    Measurement of the degree of control or limitation of the passage of smoke or products of combustion through the fire protective curtain system. Note: See limitations for the passage of smoke detailed in the Standard for the Installation of Smoke Door Assemblies and Other Opening Protectives, NFPA 105.