North America
Europe
Denmark
France
Germany
Italy
Netherlands
Poland
Spain
Sweden
Switzerland
U.K.
Latin America
Asia Pacific
Argentina
Brazil
Mexico
Australia
China
Hong Kong
India
Japan
Korea
New Zealand
UL的第三年度全球范围内的产品意识研究比以往更加广泛和深入,旨在一个更广泛的产品领域内了解制造商和消费者关注和优先考虑的重点。

更多资讯 >
UL乐于分享引以为傲的“新科学”,它通过在基础科学、测试方法、软件及标准方面一系列的研究开发,展示了UL致力于创建一个更加安全的世界的承诺。

更多资讯 >

标准

每年有数千种产品及其零部件按我们的严格要求接受测试。

仪表板

UL仪表板上的各种工具比以往更灵巧、更有效、更快捷,可使企业满足日益变迁的市场需要。

了解更多 >

资料库

标志中心

服务

标准

Share

UL 60065 - SEVENTH EDITION

(Sub) CLAUSE / ANNEX NUMBER:

Clause 4.2.4 c)

(Sub) CLAUSE / ANNEX HEADING:

Normal Operating Conditions

OTHER RELEVANT (Sub) CLAUSES / ANNEXES (as applicable):

Clause 4.2.4 a)

DESCRIPTION OF ISSUE:

What is the normal operating condition for an organ or similar keyboard instrument that contains an amplifier and a tone generator?

APPLICATION GUIDELINE:

After connection of the instrument to its RATED LOAD IMPEDANCE and depressing the 10 manual keys and 2 bass pedals (if used), adjust the output to the point of NON-CLIPPED OUTPUT POWER. Then, reduce output power to 1/8 as described in Clause 4.2.4 a)

RATIONALE:

IEC 60065 does not make it clear that power is to be reduced to 1/8 of the NON-CLIPPED OUTPUT POWER as is done for audio amplifiers. This method was confirmed at an IEC Working Group meeting and through other European test agencies.

OTHER:

None.

SEE RELATED PAG:

Clause 4.2.4 c) -- loading of organ or keyboard